44 outputs intelligent traffic controller
1.Product Function and Technical Feature:
Built-in central control system to ensure work stability;
2*48 work periods for workday and holiday setting;
Easy for maintenance and function extension by modular design;
Input AC110V and AC220V, Can be changed by the switch;
Yellow flashing or close the signal can be setup at night;
Adopt RS-232 or LAN port to communicate with upper computer;
32 working menus used for any period(among 1~30 numbers customs can set it by themselves);
The flashing state, frequency and time of each green signal light can be setup or adjusted;
Can modify the current pace of running time in the running state immediately;
Full red, yellow flashing, step by step manual,jump in the manual,remote manual function(optional);
Be equipped with the hardware fault testing function(Red Light fails,Green lights up test),down grade to Yellow flash status and cut down the Red&Green light power supply when the fault happens.(Optional)
The output part adopts zero-test technology,Change of state is zero state switch in communication,Make the drive more safe and reliable;
Each output all the way with independent lightning protection circuit;
Installation testing capabilities,can test to confirm installation correctness for each lamp when installation at intersection;
The clients can set up 30 menu to be backup and recovery ;
The setup software can operation on the computer offline,Project data can be stored on the computer and can be copied.
2.Technical Parameters:
Items | Technical Parameters |
Executive Standard | GB25280-2010 |
Working Voltage | AC110V/220V±20% (changed by switch) |
Working Frequency | 47Hz~63Hz |
No-load power | ≤15W |
The whole controller rated load power | 2200W |
Motor operation sequence(special timing state should be statement before production) | all Red(can setup) →green light→green flash can setup) →yellow light→Red light |
Pedestrian signal operation sequence | all Red(can setup) →green light→Green flash(can setup)→Red light |
Rated drive current in each way | 3A |
surge current in each way | ≥100A |
The largest output channel independently | 44 |
The largest output way independently | 16 |
working menus | 32 |
Can be setup menus number | 30 |
The largest number of each meus | 24 |
The largest number of timers in each day | 48 |
Running time in each step | 1~255 |
Full red transition time | 0~5S |
Yellow light transition time | 1~9S |
Green flashing time | 0~9S |
OperationalTemperatureRange | -40℃~+80℃ |
Relative Humidity | <95% |
Setting Plan Saving Time(the electricity was turned off) | 10 years |
Time Error | Error/year<2.5 minutes (25±1℃) |
Inner Cabinet Dimension | 472.6*215.3*280mm |
Outer Cabinet Dimension | 1250*630*500mm |
Special Function Operations:
Introduction to the function of side-door switches and buttons